<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-21 22-45-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 71 dBuV YLESUOMI
Pilot RDS Phase Difference
6.9 kHz 3.4 kHz 75 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 70 kHz 19060 13,5677
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 4,76 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 10 (Pop M) 1 0 1 1 22:45, 21.01.2025
RT
" - toivei "
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6205, 6201, 6202, 6207
FM Scope Max at: 70 kHz MIN: 9 kHz % above 76 kHz: 13,5677 Acquired: 2025/01/21 22.44.13 Total samples: 19060 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,8 dBr MIN: 2,0 dBr AVE: 4,76 dBr % above 12,2 dBr: 0,0 Last value: 2,8 dBr (2025/01/21 22.44.13) 22.30 22.32 22.34 22.36 22.38 22.40 22.42 22.44 0 2 4 6 Pm [dBr]